OUR PRODUCTSCLASSIFICATION

Thermal deaerator

1、 Overview of Thermal Deaerator
The deaerator mainly aims at the problems of poor load adaptability, easy vibration, excessive dissolved oxygen in the deaerator, high heat consumption, poor actual deaerating effect and high maintenance cost of the water spray tray type, spray packing type and old thermal deaerator. It is proposed to apply the new thermal deaerator technology to reform the deaerator head of the original spray packing deaerator. Practice has proven that the thermal deaerator has achieved the goals of energy conservation, reduced consumption, improved deaeration efficiency, increased stability, and reduced maintenance costs, and has good value for promotion and use.  

2、 Technical characteristics of thermal deaerator
The thermal deaerator produced by Huaneng has been verified by hundreds of power plants to have the following advantages:
1. High deoxygenation efficiency, with a water supply qualification rate of 100%. (High pressure 5 цɡ/L, low pressure 10 цɡ/L)
2. The surplus of deoxygenation space enables the deaerator to operate significantly at overload (usually exceeding 50% of the rated output)

3. Due to its very high heat transfer efficiency, it can operate at low temperatures with full water replenishment.

4. The heat loss is greatly reduced, and the exhaust volume is controlled below 0.3% for stable operation without vibration. When the load suddenly changes by 50% and the makeup water suddenly changes by 20%, the deaerator still does not vibrate and can operate for a long time without maintenance.

5. Strong adaptability:

Adapt to high dissolved oxygen levels at the inlet (atmospheric 10000 μ g/L, high-pressure 2000 μ g/L)

Adapt to low inlet water temperature (atmospheric type 15 ℃, high-pressure type 60 ℃)

Adapt to large pressure changes (atmospheric 0.02-0.05Mpa, high-pressure 0.002-0.85Mpa)

Adapt to high water replenishment rate (100% atmospheric type, 45% high-pressure type)


3、 Technical characteristic parameter table:
CY series atmospheric thermal deaerator

  Specification and model

rated output 
T
H

Supporting water tank
volume
 M3

operation temperature 

Working pressure 
Mpa

Deoxygenation tower
External dimensions

water tank
External dimensions

CY-10

10

5

104

0.02

Φ662x2660

Φ1516x3890

CY -20

20

10

Φ812x2650

Φ1816x5250

CY -35

35

20

Φ1016x2960

Φ2420x6230

CY -40

40

20

Φ1016x3140

Φ2420x6230

CY -50

50

25

Φ1216x3140

Φ2520x7460

CY -75

75

35

Φ1416x3560

Φ2520x9340

CY -85

85

35

Φ1416x3260

Φ2820x7000

CY -130

130

40

Φ1616x3360

Φ2820x8550

CY -150

150

50

Φ1720x3380

Φ2820x9460

CY -210

210

50

Φ1820x3460

Φ3024x8560

          CYG series pressure deaerator

Specification and model

rated output 
T
H

Supporting water tank
volume
 M3

operation temperature 

Working pressure 
Mpa

Deoxygenation tower
External dimensions

water tank
External dimensions

CYG -150

150

40

158

0.58

Φ1724x3660

Φ2828x8550

CYG -200

200

50

Φ1824x3890

Φ2832x9450

CYG -250

250

60

Φ2024x4260

Φ3032x11030

CYG -420

420

80

Φ2424x4440

Φ3232x14030

CYG -680

680

100

Φ2628x4680

Φ3232x16600

  
                    
Note: The above are commonly used specifications and models. Deaerators can also be designed separately according to customer needs.


 

                                                                                                                                                                                                                                                                                                         