Maze style fan muffler

1、 Product usage and features:
The labyrinth fan muffler is an efficient noise reduction equipment produced by our company, and the GF series products are noise reduction devices used to control the aerodynamic noise caused by fans to the environment. Used for noise reduction in the inlet and outlet ducts of various centrifugal and ventilation fans.
The International Organization for Standardization (ISO) sets a noise standard of ≤ 90 decibels for such equipment, and China's new standard is the same. This is also the basis for industrial enterprises to achieve continuous noise standards. However, without using noise reduction measures, the noise emitted by the fan inlet and outlet to the environment can reach 110-120 decibels, greatly exceeding the standard requirements.
The muffler series products are impedance acoustic flow type. Our factory determines the required amount of noise reduction in the frequency spectrum range based on the frequency characteristic data obtained from actual testing of various wind turbine operation sites in power plants. This is the main basis for designing sound-absorbing sheet structures and fluid channels. At the same time, narrow rectangular channels with large sound-absorbing material finishes are used to enhance the absorption effect. This product adopts a resistive structure for noise reduction at high and medium frequencies, as well as an anti structure for noise reduction at medium and low frequencies. At the same time, two types of noise reduction zones, high frequency and low frequency, are used in the resistive channel to maximize the width of the noise reduction frequency band and achieve good noise reduction effect.
Maze type muffler, suitable for internal combustion engines, belongs to the field of power machinery manufacturing. The technical problem to be solved is to enhance the noise reduction effect and reduce exhaust resistance. Based on the directional characteristics of sound, using maze branching and changing the direction of airflow to generate relative impact, achieving soundproofing effect. The main feature is that the internal structure mainly consists of a maze wall that divides the airflow, changes direction, and generates relative impact. It is made into an airflow channel that splits in the opposite direction and converges in the opposite direction. The edge of the channel mouth is raised towards the opposite airflow direction.
After the user installs this product as required, its maximum noise level will not exceed 85-90 decibels.
2、 Product series and external dimensions:
Serial Number |
Model |
Fan nameplate air volume (ten thousand m3/h) |
Nominal size(m) |
Reference weight (kg) |
Application examples of power plant boilers (for ordering reference) |
|
B |
H |
|||||
1 |
GF-5 |
4~6 |
1.2 |
1.6 |
1750 |
N6 type steam turbine, 35T/H boiler air supply fan inlet |
2 |
GF-7 |
6~7 |
1.2 |
2.4 |
2400 |
N12 type steam turbine, 60T/H boiler air supply fan inlet |
3 |
GF-10 |
8~12 |
1.6 |
2.4 |
2950 |
N25 type steam turbine, 120T/H boiler air supply fan inlet |
4 |
GF-13 |
11~15 |
2.0 |
2.4 |
3400 |
|
5 |
GF-18 |
15~20 |
2.4 |
2.4 |
4400 |
N50 type steam turbine, 220T/H boiler air supply fan inlet |
6 |
GF-20 |
18~23 |
2.0 |
3.4 |
4650 |
|
7 |
GF-23 |
20~25 |
2.0 |
4.0 |
5500 |
N100, N125 turbine, 400T/H, 410T/H boiler air supply fan inlet |
8 |
GF-25 |
23~29 |
2.8 |
3.2 |
5850 |
|
9 |
GF-35 |
30~42 |
4.0 |
3.0 |
7200 |
|
10 |
GF-45 |
38~50 |
4.0 |
3.2 |
10500 |
N200 type steam turbine, 670T/H boiler air supply fan inlet |
11 |
GF-50 |
45~60 |
4.8 |
4.0 |
13600 |
|
12 |
GF-60 |
50~70 |
5.2 |
4.0 |
14400 |
N310 type steam turbine, 1000T/H boiler axial flow fan inlet air |
13 |
GF-70 |
60~85 |
5.0 |
4.0 |
18500 |
|
14 |
GF-90 |
75~100 |
5.5 |
5.5 |
21000 |
|
15 |
GF-100 |
90~115 |
5.6 |
6.0 |
23000 |
|
Note: Our company can design mufflers with any specifications based on user provided parameters such as flow rate and interface size!
Related products:
Previous article: Return to List
Next article: Honeycomb fan muffler