OUR PRODUCTSCLASSIFICATION

Fan silencer

 1、 Usage and characteristics of fan muffler products:
The GF type fan muffler series products produced by our company are noise reduction devices used to control the aerodynamic noise caused by fans on the environment. Used for noise reduction in the inlet and outlet ducts of various centrifugal and ventilation fans.
Industrial fans are continuous operating equipment. The International Organization for Standardization (ISO) sets a noise standard of ≤ 90 decibels for such equipment, and China's new standard is the same. This is also the basis for industrial enterprises to achieve continuous noise standards. However, without using noise reduction measures, the noise emitted by the fan inlet and outlet to the environment can reach 110-120 decibels, greatly exceeding the standard requirements.  
The muffler series products are impedance acoustic flow type. Our factory determines the required amount of noise reduction in the frequency spectrum range based on the frequency characteristic data obtained from actual testing of various wind turbine operation sites in power plants. This is the main basis for designing sound-absorbing sheet structures and fluid channels. At the same time, narrow rectangular channels with large sound-absorbing material finishes are used to enhance the absorption effect. This product adopts a resistive structure for noise reduction at high and medium frequencies, as well as an anti structure for noise reduction at medium and low frequencies. At the same time, two types of noise reduction zones, high frequency and low frequency, are used in the resistive channel to maximize the width of the noise reduction frequency band and achieve good noise reduction effect.  
At the same time, our company also produces two forms of mufflers: honeycomb mufflers and labyrinth mufflers.  
After the user installs this product as required, its maximum noise level will not exceed 85-90 decibels.  

2、 Fan silencer product series and external dimensions:
Serial Number
Model
Fan nameplate air volume
ten thousand m3/h)
Nominal size(m)
Reference weight
(kg)
Application examples of power plant boilers (for ordering reference)
B
H
1
GF-5
4~6
1.2
1.6
1750
N6 type steam turbine, 35T/H boiler air supply fan inlet
2
GF-7
6~7
1.2
2.4
2400
N12 type steam turbine, 60T/H boiler air supply fan inlet
3
GF-10
8~12
1.6
2.4
2950
N25 type steam turbine, 120T/H boiler air supply fan inlet
4
GF-13
11~15
2.0
2.4
3400
 
5
GF-18
15~20
2.4
2.4
4400
N50 type steam turbine, 220T/H boiler air supply fan inlet
6
GF-20
18~23
2.0
3.4
4650
 
7
GF-23
20~25
2.0
4.0
5500
N100, N125 turbine, 400T/H, 410T/H boiler air supply fan inlet
8
GF-25
23~29
2.8
3.2
5850
 
9
GF-35
30~42
4.0
3.0
7200
 
10
GF-45
38~50
4.0
3.2
10500
N200 type steam turbine, 670T/H boiler air supply fan inlet
11
GF-50
45~60
4.8
4.0
13600
 
12
GF-60
50~70
5.2
4.0
14400
N310 type steam turbine, 1000T/H boiler axial flow fan inlet air
13
GF-70
60~85
5.0
4.0
18500
 
14
GF-90
75~100
5.5
5.5
21000
 
15
GF-100
90~115
5.6
6.0
23000
 




 
Related products:
 Central air conditioning noise control Cooling tower noise control  Fan noise control Pump room noise control  Noise control of ball mill
Turbine soundproof cover Fan silencer Steam emission muffler Blow pipe silencer Safety door silencer
Dust removal fan muffler Roots blower silencer   Honeycomb fan muffler  Maze style fan muffler   

Previous article: Steam emission muffler