OUR PRODUCTSCLASSIFICATION

damper

1、 Overview of barrier door products:
The baffle door is produced and manufactured with technology introduced by Lianyungang Huaneng Power Auxiliary Equipment Co., Ltd. It is used on the inlet, outlet or bypass flue of the flue gas system absorption tower, or in the flue gas denitrification and dust removal system. The desulfurization flue gas baffle door usually adopts a louver type double-layer baffle structure. When closed, sealed air is introduced between the double-layer baffles for gas sealing, achieving the function of isolating and shutting off the flue gas.

According to their shape, they can be divided into square single axis double baffle doors and circular single axis double baffle doors; According to the driving mode, it can be divided into electric single axis double speed plate door and pneumatic single axis double speed plate door; According to the usage location, it can be divided into original flue gas damper damper damper at the inlet of FGD, net flue gas damper damper damper at the outlet of FGD, bypass flue gas damper damper damper at FGD, inlet damper damper damper of FGD booster fan, and outlet damper damper damper of FGD booster fan, etc; According to the material, it can be divided into carbon steel type single axis double baffle doors, stainless steel type single axis double baffle doors, and nickel based alloy type single axis double baffle doors.

          Schematic diagram of baffle door sealing 

2、 Performance characteristics of barrier doors:
1. The desulfurization flue gas baffle door adopts a single axis driven double louver baffle structure, with a sealed chamber designed in the middle of the double-layer blades to introduce sealed air. The sealed air above the flue gas pressure is introduced into the baffle, forming a sealed air isolation layer between the double-layer baffles to block the passage of flue gas flow.  

2. The opening and closing time of the desulfurization flue gas damper door is ≤ 60 seconds (can be selected according to user requirements).

3. The external design has a connecting rod mechanism that allows several blades to open or close synchronously. The shaft seal device is separated from the rolling bearings, making it easy to adjust and maintain without bearing corrosion defects.

4. The design structure of the double louver flue gas baffle door is reasonable, with good blade rigidity and stable and reliable operation. The sealing type of the louver baffle blade is elastic seal or gas seal.

5. The desulfurization flue gas baffle door can be driven in multiple ways: electric or pneumatic.

6. The air seal fan and door panel are controlled by a mechanical linkage mechanism, which is safe and reliable.

     Structural diagram of double sealed baffle door

3、 Structural characteristics of desulfurization flue gas baffle door:

The desulfurization flue gas baffle door is mainly composed of several parts, including frame, blades, sealing plates, main shaft, bearings, shaft seals, crank connecting rod mechanism, actuator, and sealed air system (auxiliary system). Huaneng's production framework is formed by steel plate compression molding or rigid welding, and the blades are formed by steel plate compression molding and welding. There are special elastic sealing structures between the blades and between the blades and the frame. The blades are made into hollow cavities. When the blades are in the closed position, a mechanical sealing barrier is first formed on the flue section, and then sealed air with a pressure higher than the working medium pressure is introduced to form a high-pressure sealed air curtain wall, completely separating the front and rear of the blades and ensuring 100% partition effect.
The journal of the Huaneng baffle door adopts a special sealing structure and special bearings. The special sealing structure has good sealing performance, no leakage, high temperature resistance, and corrosion resistance. The special bearings have automatic centering and automatic compensation functions.

4、 Technical parameters of desulfurization flue gas baffle door:
1. Flue section: W (width) x H (height) x L (thickness);  
2. Applicable medium: cold and hot flue gas;  
3. Design temperature resistance: ≤ 300 ℃;  
4. Design pressure: ± 8500Pa;
5. Leakage rate of smoke inside and outside: "0"
6. Drive mode: electric or pneumatic;  
7. Power and control requirements: to be selected by the user.


damper       

Specification parameters:

model

HG-10

HG-20

HG-30

HG-50

HG-75

HG-100

internet traffic L/H

600

1200

1800

3000

4500

6000

Working pressure MPa

≤0.3

Working vacuum MPa

-0.06~0.09

Operating temperature

40-60

water content PPM

≤8

impurity μm

≤5

Power KW

6

12

24

32

48

64

total power KW

8

14

26

36

54

76

weight Kg

350

480

520

580

820

1050

                                                                                                                                                                                                                                                                                                                                                               

Related products:
                

slide plate gate

damper

flap gate

explosion vent

Electric plug-in door

Hot air isolation door

Desulfurization baffle door

Smoke barrier door

Single axis double speed plate door

Adjust the baffle air door

Quickly open the barrier door

Bypass baffle door

Quick opening flue plug door

Balanced adjustable shrinkage hole

Denitrification barrier door

Split type adjustable shrinkage hole

Single core adjustable shrinkage hole

Desulfurization flue damper door

seal plate

Coal bunker plug-in door

Smoke isolation door

 

 

 

 

 

 

Previous article: slide plate gate
Next article: Coal mill isolation door